Essential Site Maintenance: Authorea-powered sites will be updated circa 15:00-17:00 Eastern on Tuesday 5 November.
There should be no interruption to normal services, but please contact us at help@authorea.com in case you face any issues.

Huisheng Gao

and 5 more

Chenxi Liu

and 3 more

The ever-increasing adoption of power electronic converters for renewable integration and energy-saving applications has weaken grid and caused new types of small-signal stability issues, such as sub-/super-synchronous oscillations, resulting from the interaction between the fast-acting converter control and the power network. It is challenging to analyze the small-signal stability issues by grid strength assessment due to the complex interaction between many converter-interfaced generators (CIGs) and the power network in a multi-CIG system (MCIGS). This complexity is further increased when considering different non-rated operating conditions of each CIG, such as their actual power injections and terminal voltages, which manifest the heterogeneity in the MCIGS. Moreover, in such a heterogeneous MCIGS, it is difficult to characterize the small-signal stability boundary under non-rated operating conditions. To address the challenges, this paper derives generalized operational short-circuit ratio (gOSCR) and critical gOSCR (i.e., CgOSCR) by the small-signal stability analysis in such a heterogeneous MCIGS. Based on gOSCR and CgOSCR, a method is proposed for grid strength assessment to identify the small-signal stability issues in such a heterogeneous MCIGS. This proposed method can be used when CIGs are modeled by either black-box or white-box modeling in a MCIGS under non-rated operating conditions. More importantly, the proposed method can also be used to assess grid strength in terms of the static voltage stability in a MCIGS under non-rated operating conditions, since the static voltage stability issue is a special case of the small-signal stability issue with focus on zero frequency band for converter controls. The efficacy of the proposed method is demonstrated in the IEEE 39-bus system and a practical power system with a large-scale renewable integration.

Yuhan Zhou

and 5 more

While renewable resources are increasingly integrated into the electric power grid, the small-signal instability risk may be induced by grid-following converters using phase-locked loops (PLLs) for grid synchronization, especially under weak grid conditions. The analysis of the instability mechanism is complex in a multi-converter system due to the dynamic interaction between PLL-based converters and the power network. The analysis complexity is further increased in a heterogeneous multi-converter system (HMCS), where all converters have different control configurations and parameters from different manufacturers. To understand how the different PLL dynamics collectively affect the stability of the HMCS, this paper analytically derives the small-signal stability boundary condition of the HMCS dominated by the PLL dynamics (HMCS-DPLL). The derived stability boundary allows us to obtain analytical results about how the stability of the HMCS-DPLL is affected by grid strength, converter operating conditions, different PLL control parameters and the interaction among different PLLs. Based on the stability boundary condition, a computationally efficient method is also proposed to identify the design rationality of PLL control parameters as well as the small-signal stability and stability margin of the HMCS-DPLL. The analytical results and proposed method are validated by modal analysis and electromagnetic transient simulation with detailed models on a 9-converter heterogeneous system.

Yuhan Zhou

and 7 more

The increasing penetration of renewable resources into the power network through grid-following converters has increased the risks of oscillation instability. In such a power system, it is challenging for assessing the small-signal stability due to the complex interaction among converters interconnected through the power network. Moreover, the assessment complexity is further increased in a heterogeneous multi-converter system, where the interconnected converters have different control configurations or parameters from different manufacturers. To tackle the challenges, this paper proposes a method for the small-signal stability analysis of a heterogeneous multi-converter system. To this end, it is first theoretically proved that the small-signal stability of a heterogeneous system can be characterized by an equivalent homogeneous one, where all interconnected converters have the same control configurations and parameters. This can reduce the complexity of the small-signal stability assessment of the original heterogeneous system by decoupling the equivalent homogeneous system into a set of subsystems. To further reduce the assessment complexity, it is derived that the small-signal stability and stability margin of the heterogeneous system can be estimated based on the smallest eigenvalue of a weighted Laplacian matrix of the power network. Based on the analysis results, a scalable method is developed for assessing the small-signal stability of heterogeneous multi-converter systems. The efficacy of the proposed method is validated by performing both modal analysis and time-domain simulations on two heterogeneous multiple-converter systems with different network sizes and converter numbers.