The better can be the enemy of the good. The timing of LV venting during complex open...
Francesco Ferraro
Herve Schlotterbeck

Francesco Ferraro

and 4 more

January 31, 2024
We report a young female patient with a complex cardiac surgical history that underwent a redo complex aortic valve replacement. In the context of severe AR and dilated LV, we experienced that it is safer to start the LV venting after aortic cross clamping. In this setting NIRS can be, in this particular context, a useful monitoring tool to prevent potential severe neurological damage.