Assessment of The Correlation Between Doppler Derived dP/dt and Aortic Velocity-time Integral During Cardiac Resynchronization Therapy Optimization
  • Selim Ekinci,
  • Hakan Gökalp Uzun
Selim Ekinci
Izmir Il Saglik Mudurlugu Izmir Saglik Bilimleri Universitesi Tepecik Egitim ve Arastirma Hastanesi

Corresponding Author:mdsekinci@gmail.com

Author Profile
Hakan Gökalp Uzun
Izmir Il Saglik Mudurlugu Izmir Saglik Bilimleri Universitesi Tepecik Egitim ve Arastirma Hastanesi
Author Profile

Abstract

Suboptimal response to cardiac resynchronization therapy (CRT) may be improved by optimization of device parameters using echocardiography. For this purpose, the aortic velocity-time integral (aVTI) was used as a target metric to define optimal velocity timings for each ventricle. dP/dt is a parameter used for the assessment of myocardial contractility. In this study, we aimed to evaluate the effectiveness of Doppler-derived dP/dt in optimization by assessing the possible correlation between aVTI and dP/dt. Patients with CRT admitted for routine follow-up were included in the study. Aortic VTI and dP/dt measurements were recorded in four different standard pacing configurations during reprogramming. A total of 46 patients were included in the final analysis. No correlation was found between the aVTI and the delta dP/dt value in the two configurations where the change in dP/dt was maximum (p=0.894). In the two configurations where the change in aVTI was maximum, there was also no correlation between the delta dP/dt and the delta aVTI (p=0.715). When patients were dichotomized according to the median value of dP/dt, there were no differences in aVTI, NYHA classes, LVEF, and mitral regurgitation (MR) severity (p=0.4; p=0.5; p=0.7; p=0.3; respectively). The change in both dP/dt and aVTI was statistically significant when switching from RV-only to QRS width-targeted configuration (p=0.001; p=0.041; respectively). In conclusion, aVTI recorded at different pacing configurations was not correlated with dP/dt during interventricular optimization. However, both parameters consistently showed a positive effect of biventricular pacing on contractile synchronization and stroke volume.