Redo aortic valve replacement with a non-conventional intraoperative
decision to avoid left main stem obstruction.
- Thomas Theologou,
- Depaksi Tare,
- Sara Clivio,
- Demertzis S,
- Enrico Ferrari
Thomas Theologou
Universita della Svizzera italiana Facolta di scienze biomediche
Corresponding Author:thomas.theologou@gmail.com
Author ProfileDepaksi Tare
Universita della Svizzera italiana Facolta di scienze biomediche
Author ProfileDemertzis S
Universita della Svizzera italiana Facolta di scienze biomediche
Author ProfileEnrico Ferrari
Universita della Svizzera italiana Facolta di scienze biomediche
Author ProfileAbstract
Redo aortic valve surgery for failure of a previously implanted valve is
always challenging. In case of small-sized implanted valves, the use of
a balloon-expanding Sapien-3 valve can enhance the final effective
orifice area, avoid complex annulus enlargement techniques, and can
reduce operative time and morbidities. We describe a case where after
explanting a failed 19mm St. Jude mechanical aortic valve and further
deployment of a 23mm Sapien-3 valve, the left coronary ostia was
obstructed by the skirt of the transcatheter prosthesis. After careful
removal of a little part of the skirt, we were able to restore the
coronary flow and the patient had a favorable outcome.05 Jan 2022Submitted to Journal of Cardiac Surgery 06 Jan 2022Submission Checks Completed
06 Jan 2022Assigned to Editor
10 Jan 2022Reviewer(s) Assigned
23 Jan 2022Review(s) Completed, Editorial Evaluation Pending
24 Jan 2022Editorial Decision: Revise Minor
02 Mar 20221st Revision Received
04 Mar 2022Submission Checks Completed
04 Mar 2022Assigned to Editor
04 Mar 2022Reviewer(s) Assigned
13 Mar 2022Review(s) Completed, Editorial Evaluation Pending
14 Mar 2022Editorial Decision: Accept