loading page

Intramucosal esophageal dissection caused by gastric tube insertion
  • Ryo Ichibayashi,
  • Masayuki Watanabe,
  • Mitsuru Honda
Ryo Ichibayashi
Toho University Omori Medical Center

Corresponding Author:ryou.ichibayashi@med.toho-u.ac.jp

Author Profile
Masayuki Watanabe
Toho University Omori Medical Center
Author Profile
Mitsuru Honda
Toho University Omori Medical Center
Author Profile

Abstract

We experienced a case of iatrogenic intramucosal esophageal dissection in a patient who had difficulty inserting a gastric tube. CT is useful for diagnosis.
12 Apr 2022Submitted to Clinical Case Reports
13 Apr 2022Submission Checks Completed
13 Apr 2022Assigned to Editor
15 Apr 2022Reviewer(s) Assigned
22 May 2022Review(s) Completed, Editorial Evaluation Pending
22 May 2022Editorial Decision: Revise Minor
25 May 20221st Revision Received
26 May 2022Submission Checks Completed
26 May 2022Assigned to Editor
26 May 2022Review(s) Completed, Editorial Evaluation Pending
30 May 2022Editorial Decision: Accept
Jun 2022Published in Clinical Case Reports volume 10 issue 6. 10.1002/ccr3.5996